{
"id": "https://doi.org/10.5281/zenodo.1407498",
"doi": "10.5281/ZENODO.1407498",
"types": {
"ris": "JOUR",
"bibtex": "article",
"citeproc": "article-journal",
"schemaOrg": "ScholarlyArticle",
"resourceType": "Journal article",
"resourceTypeGeneral": "Text"
},
"creators": [
{
"name": "Dr. Shakeel Ahmad, Dr. Samra Kanwal, Dr. Muhammad Haroon Haider",
"nameType": "Personal",
"affiliation": []
}
],
"titles": [
{
"title": "The Outcome Of Using (5.5 Mm) Self-Sealing Limbal Incision For Eyes With (1.5 – 3.0) D Pre-Existing Astigmatism On The Steepest Meridian"
}
],
"publisher": {
"name": "Zenodo"
},
"container": {},
"subjects": [
{
"subject": "Steepest meridian (SM), Pre-existing astigmatism (PEA), Self-sealing Limbal Incision (SSLI), Keratometry outcome, Limbal Incision (LI)."
}
],
"contributors": [],
"dates": [
{
"date": "2018-09-01",
"dateType": "Issued"
}
],
"publicationYear": 2018,
"language": "en",
"identifiers": [
{
"identifier": "https://doi.org/10.5281/zenodo.1407498",
"identifierType": "DOI"
},
{
"identifier": "https://zenodo.org/record/1407498",
"identifierType": "URL"
}
],
"sizes": [],
"formats": [],
"rightsList": [
{
"rights": "Creative Commons Attribution 4.0",
"rightsUri": "https://creativecommons.org/licenses/by/4.0"
},
{
"rights": "Open Access",
"rightsUri": "info:eu-repo/semantics/openAccess"
}
],
"descriptions": [
{
"description": "Objective: The research objective is to calculate keratometry results of a 5.5 mm self-sealing incision in eyes, having astigmatism pre-existed, on the sharpest/steepest meridian.\n\nMethodology: A prospective researched method was observed upon thirty-five eyes having astigmatism (with or against 1.5 to 3 D) pre-existed at Service Hospital, Lahore (October 2016 September 2017). A 1.5 mm incision, 120 degrees approximate separation each, was used for the performance of Bi-manual phaco. A third self-sealing limbal incision which was created on the steepest meridian was used for the implantation of IOL. Before operating, keratometry reading was taken for the assessment. After twelve weeks of operation, automated keratometry was recorded.\n\nResults: Average pre-existing reduction against the rule astigmatism was 1.15 with SD equal to 0.33 and with the rule astigmatism was 1.47 with SD equals to 0.32.\n\nConclusions: Our research outcome reports that by placing a third 5.5 mm incision and determining the steepest meridian, the possibility of low astigmatic outcomes is achievable with/against the rule of astigmatism pre-existed in the eyes.\n\nKeywords: Steepest meridian (SM), Pre-existing astigmatism (PEA), Self-sealing Limbal Incision (SSLI), Keratometry outcome, Limbal Incision (LI).",
"descriptionType": "Abstract"
}
],
"geoLocations": [],
"fundingReferences": [],
"relatedIdentifiers": [
{
"relationType": "IsVersionOf",
"relatedIdentifier": "10.5281/zenodo.1407497",
"relatedIdentifierType": "DOI"
}
],
"schemaVersion": "http://datacite.org/schema/kernel-4",
"providerId": "cern",
"clientId": "cern.zenodo",
"agency": "datacite",
"state": "findable"
}